RAM DA-2000 SERIES - MULTI-PURPOSE SURVEY METER
The RAM DA-2000 series was developed to solve the problem of rapid instrument obsolescence. The
flexibility and modularity of the RAM DA makes it possible to maintain the highest standards of safety, by
using different types of detectors for different applications.
Applications:
Nuclear Power Plants, nuclear and medical research centers, H.P. departments, radiology clinics,
radiation and environmental protection authorities.
Features:
Communication to PC Calendar/Clock, Non-volatile memory.
Two output relay contacts for threshold and failure alarm.
RMV (Rotem Meter View) compatible.
Different types of detectors can be connected.
Automatic detector identification and selection of readout units.
Freeze mode to record the highest dose rate.
Manually set alarm threshold.
Low battery & Overflow alarm.
Ability to display several units of measurement (cps, cpm, uSv/h, mR/h, counts…).
RAM DA-2000 / RAM DA-3 2000
MAIN DETECTORS FOR RAM DA 2000
GM-40 Series (GM-40, GM-41, GM-42)
For Gamma Radiation over a
very wide range.
Based on different types of
energy compensated GM tubes.
Extended hook-up cable of up
to 100 meters can be used.
GM-10 Detector
Efficient surface monitoring
of alpha, beta and gamma
radiation contamination,
based on 1¾” Pancake GM
tube.
Sensitivity (
137
Cs):
~350 cpm/µSv/h
(3500 cpm/mR/h)
Measuring Range:
0 to 42,000 cps
PA-100 Detector
Surface monitoring for Alpha
contamination.
Based on Ionization chamber.
Very easy to maintain.
100 cm
2
(15.5 sq. in.)
IC-10 Detector
Wide range gamma, x-ray and
beta radiation measurement.
Based on 0.5 liter atmospheric
ionization chamber.
Uses special features and
advanced technology.
Gamma scintillation probe
for improved x-ray and low
energy gamma radiation
detection,based on thin Nal 2”
diameter scintillator
(2” dia. X 0.04” thickness).
S.C.A. can be set within the
energy range, optimized for
125
I
detection and/or other isotopes.
Scintillation probe for high
energy gamma radiation
detection.
Nal 2” x 2” diameter scintillator.
Single channel analyzer (SCA)
– optional.
MULTI-RANGED “SMART” SURVEY METERS
RAM ION Digilog
RAM ION with wireless communication
Features:
Built in wireless transmitter
(900 MHz or 2.4 GHz spread spectrum).
Data Logging capability.
User selectable transmitting intervals.
Compatible to most data collecting
software platforms.
TelePole: A GM meter on an extendible pole
The TelePole is a microprocessor based telescopic rate meter
Features:
Energy compensated GM tubes.
Rugged and lightweight.
Data Logging capability.
“DigiLog” – combined digital and analog display.
“Smoothed” display for minimum readout fluctuations.
IRP-51-H*(10) version available
Manual or Computerized calibration system.
RS-232 Communication Port.
Optional built in wireless transmitter (900 MHz or 2.4 GHz spread spectrum).
Length: From 107 cm up to 337 cm (from 3.5ft up to 11ft.).
Applications:
Supports ALARA principles by allowing operators to obtain readings as much as
eleven feet away from high radiation fields.
Routine survey instrument with storage and downloading of data to SMARTS.
Readings of hard to reach areas (e.g. vehicle surveys, elevated piping, etc.).
PM-10 Detector
PM-11 Detector
Features:
Ion chamber (500cc) survey meter
Auto ranging Digital and Analog display, combines fast response and readout stability.
Data Logging capability.
Large size character digits.
Built in memory.
Metal front panel.
User adjustable threshold alarm.
Manual or computerized calibration software.
Allows for storage of data points and on-line diagnostics.
IRP-51-H*(10) version available
Applications:
Replaces traditional ion chambers for all outage and routine requirements.
Real-time beta and gamma area monitoring with the TeleMap system.
Optional - built in bar-code laser scanner.
RS-232 serial port for downloading of data to Smarts program.
ALARA hot spot tracking.
Ideal for logging of bar-code location identification and plant survey data, which is
then transferred to SMARTS.
RAM DA-3 2000 Measuring Range: 0.5 µSv/h to 1 Sv/h (50 µR/h to 100 R/h)
RAM DA-2000 series: Without internal detector
RAM DA-3 2000 series: With wide range internal detector
Wide Range Monitoring : 1 µSv/h to 500 mSv/h (0.1 mR/h to 50 R/h)
Wide Range: 0.5 µSv/h to 10 Sv/h (0.05 mR/h to 1,000 R/h)
High Range: 50 µSv/h to 10 Sv/h (5 mR/h to 1,000 R/h)
Optional Detector (in the meter): 0.5 µSv/h to 10 mSv/h (0.05 mR/h to 1 R/h)
TeleMap Online Monitoring System
The TeleMap Software package continuously monitors radiation levels.
The system collects data on line from detectors in the field and displays them
on area maps.
Data can be collected using either RS-485 communications protocol and/or
wireless network.
A modular system, used in nuclear power plants, to collect radiation
levels on-line for instant appraisal.
Measuring Range:
1.0 µSv/h to 250 mSv/h
(0.1 mR/h to 25 R/h)
Surface Sensitivity:
530 cpm per Bq/cm
2
Measuring Range:
0 to 50,000 cps
Surface Sensitivity (in contact):
131
I: 320 cpm/Bq/cm
2
99m
Tc: 315 cpm/Bq/cm
2
Measuring range: 0 to 50,000 cps
Energy range: 10 to 80 keV
125
I surface sensitivity: 440 cpm/Bqcm
2
Measuring range: 0 to 50,000 cps
Measuring Range:
GM-40: 250 µSv/h to 10 Sv/h
(25 mR/h to 1000 R/h)
GM-41: 50 µSv/h to 1 Sv/h
(5 mR/h to 100 R/h)
GM-42: 0.5 µSv/h to 10 mSv/h
(50 µR/h to 1 R/h)
Two Models: Wide Range and High Range
MEDISMARTS: A UNIQUE ON-LINE RADIATION MONITORING SYSTEM
The MediSmarts system is designed to measure and collect radiation data automatically and continuously
from cyclotron facilities, radiochemistry laboratories,treatment rooms and PET Centers. Radiation is
monitored by a variety of detectors and results are transferred through a series of monitoring channels
to a central computer located in the control room.
PET Monitoring and Nuclear Medical Departments
Our Area Radiation Monitoring is based on field proven, highly
reliable radiation detectors, Data Processing Units and unique
Computer Software. The system provides real time on line radiation
levels. The data is used for both radiation safety and improving the
site operation.
The Basic Monitoring
Channel consists of:
Data Processing Unit (DPU)
Detector
Connection Box
Cables
Some Monitoring Channels:
Optional Local
Alarm Unit
Optional Remote
Display Unit
GM-41 Area Monitoring Channel
Used in the Cyclotron vault and in the Hot Cells. Can be set to report activity and is
useful to measure the activity before the material is moved out of the Hot cell into the
Dose Calibrator. (dose and dose rate)
GM-42 Area Monitoring Channel
Used in the Radiochemistry Lab, Control Room, Q.A. Dept, Radiopharmacy and other
rooms to measure general radiation (dose and dose rate).
PM-11 Stack Monitoring Channel
High Sensitivity detector used in the Exhaust Stack to measure radioisotope releases,
down to the 10-
7
μCi/cc regulatory requirements. Combined with online readings from
the flow meter, provides full reporting on released concentration and amounts.
Features:
Stack Monitoring with quantitative activity release measurement.
Area Monitoring.
Production Monitoring.
Comprehensive radiation analysis software.
Site Safety Control.
Automatic Activity Release Report.
Automatic calculation of the total activity for selected period of time.
Measuring Range: 1 μSv/h to 1 Sv/h (0.1 mR/h to 100 R/h)
Measuring Range: 0.1 μSv/h to 10 mSv/h (0.01 mR/h to 1 R/h)
The following detectors, including underwater installed,
can be used to collect the data:
RAM ION, TelePole, DRM-1, DRM-1D, RAM R-200, AMP-50,
AMP-100 and AMP-200.
IRP-51-H*(10) version available
IRP-51-H*(10) version available
Features:
Energy compensated GM tube.
Data Logging capability.
Different types of detectors can be connected.
Automatic detector identification and selection of readout units.
Ability to display several units of measurement (cps, cpm, µSv/h, mR/h, counts…).
Applications:
Nuclear Power Plants, nuclear and medical research centers, H.P. departments,
radiology clinics, radiation and environmental protection authorities.
RAM DA-2000 / RAM DA-3 2000
Measuring Range: 0.5 µSv/h to 1 Sv/h (50 µR/h to 100 R/h)
Measuring range: 0 to 50,000 cps