RAM 4000 Manual do Utilizador Página 6

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 14
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 5
6
MANUAL - UG4000 SERIES SPRAY GUN CLEANERS REVISED 2012-03A
OPERATION
To activate the Fume Vent during use, turn the lever labelled "Air Vent" to the open (vertical) position.
PRE - CLEAN
Disconnect the spray gun from the air hose. Pour paint from the cup (when present) into a 5 gallon
pail (not supplied).
Rinse cup with solvent and pour into the same 5 gallon pail for later disposal or recycling.
CLEANING SPRAY GUNS AND CUPS
Loosen the air cap of the spray gun two full turns.
Lock the trigger in the open position with the Trigger Lock Spring.
To prevent liquid from entering the air passgae during automatic cleaning, insert the white plastic Air
Passage Plug into the Spray Gun's air inlet. If the air inlet has a male threaded connector instead of a
quick connect use the knurled nut attached to the Trigger Clamp (included).
Place spray guns facing corner jets. Placement depends on type of spray gun. See pictures below.
Place cups onto the low spray jets and cup holders.
Note: Gravity Feed Spray Gun: Some customers prefer to clean the cup separate
from the spray gun.
Close the lid and turn the “Auto Wash Timer” knob clockwise to start cleaning.
The cleaning cycle takes about 60 seconds
Push and hold the "Air Rinse" button for about 3 second to air-rinse the guns.
Push and hold the "Clean Rinse" button for about 5 seconds to rinse guns with clean solvent. This
will send a pre-set amount of clean solvent (100 cc) through the jets. Wait 30 seconds for the Rinse
Pump to fully recharge before repeating.
The solvent flow per clean-rinse cycle is limited to 100 cc to minimize consumption. This quantity is
usually sufficient to clean the inside passages of the spray guns.
FUME VENT CONTROL
The Vent Control on the right side can be used to turn the Vent off when the unit is not being used.
MANUAL WASH
If you have the UG4000FS model, make sure the Brush ON/OFF handle (front) is in the ON position.
Open the lid and step on the foot pedal. A dedicated pump delivers wash solvent through the brush.
when the foot pedal is depressed. To control the flow of solvent through the Brush, adjust the Flow
Control, also on the front of the unit.
MANUAL RINSE (UG4000FS)
Place the Brush ON/OFF handle (front) in the OFF position.
Open the lid and step on the foot pedal. A venturi delivers clean rinse solvent through the fixed spigot
when the foot pedal is depressed.
HOSE CLEANING (UG4500E)
This model can be used to clean a paint feeder hose up to 100 feet (30 m) long. Connect the hose to
the two fittings, one on the front and one on the right side. Rotate the "Mode Selector" handle to the
horizontal position and turn the Timer knob clockwise to start the automatic cleaning cycle.
To air-rinse the hose, push and hold the "Air Rinse” button.